AI Data Center (Liquid Cooling) Daily Report Template

209+ fields across 15+ sections. NFPA 75/76, ASHRAE TC 9.9, ASME B31.9 compliant. Preview every field below — subscribe to download.

PLAN OF DAY
POD Daily Report Template

AI Data Center (Liquid Cooling)

Construction Daily Report — 6 industry sections + 8 common sections

0
Total Fields
90
Industry Fields
98
Common Fields
45
KPI Mapped
NFPA 75/76ASHRAE TC 9.9ASME B31.9Uptime Tier
© 2026 Plan of Day, Inc. All rights reserved.planofday.com

Common Sections (98 fields shared across all industries)

AI Data Center (Liquid Cooling) — Industry Sections (90 fields)

Field NameTypeUnitRequiredPOD KPI
CDU (Coolant Distribution Unit) InstalledIntegercountRequired
CDU Manufacturer / ModelTextRequired
CDU Cooling CapacityNumberkWRequired
CDU LocationTextrow/zoneRequired
Rear-Door Heat Exchangers (RDHx) InstalledIntegercountRequiredCostPerInstallUnit
RDHx CapacityNumberkWRequired
Direct-to-Chip Cold Plates InstalledIntegercountRequired
Direct-to-Chip Manifolds InstalledIntegercountRequired
Coolant Piping - Primary LoopNumberLFRequired
Coolant Piping - Secondary LoopNumberLFRequired
Coolant Pipe SizeTextinchesRequired
Coolant Pipe MaterialEnumSS/Copper/PEXRequired
Coolant TypeEnumPropylene Glycol-Water/DI Water/DielectricRequired
Coolant Charge VolumeNumbergalRequired
Coolant ConcentrationNumber%Required
Leak Testing - PressureNumberPSIRequired
Leak Testing - DurationNumberhrsRequired
Leak Testing - ResultEnumPass/FailRequiredInspectionFirstPassRate
Quick-Connect Fittings InstalledIntegercountRequired
Drip Containment / Leak DetectionEnumN/S / Installed / TestedRequired
Leak Detection Sensors InstalledIntegersensorsRequired
Coolant Filtration SystemEnumN/S / Installed / TestedRequired
Immersion Cooling Tanks (if applicable)IntegertanksBest Practice
Immersion Fluid TypeTextBest Practice
Immersion Fluid VolumeNumbergalBest Practice
Field NameTypeUnitRequiredPOD KPI
HVDC Bus VoltageEnum400VDC / 800VDCRequired
HVDC Bus InstalledNumberLFRequired
Rectifier Units InstalledIntegercountRequired
Rectifier Unit RatingNumberkWRequired
DC PDU InstalledIntegerunitsRequired
DC PDU RatingNumberkWRequired
DC Busbar InstalledNumberLFRequired
DC Busbar AmpacityNumberARequired
DC Busbar MaterialEnumCopper/AluminumRequired
DC Power Testing - Voltage RegulationNumber%Required
DC Power Testing - RippleNumber%Required
DC Power Testing - EfficiencyNumber%Best Practice
Power Conversion Efficiency (AC→DC)Number%Best Practice
Field NameTypeUnitRequiredPOD KPI
Custom Racks InstalledIntegercountRequiredCostPerInstallUnit
Rack Weight (loaded)NumberlbsRequired
Rack Power RatingNumberkWRequired
Rack Power Whip ConnectionEnumN/S / Connected / TestedRequired
Rack Power Whip RatingNumberkWRequired
Power Whips InstalledIntegercountRequired
Network Patch Panel InstalledIntegerpanelsRequired
Network Ports Per RackIntegerportsRequired
Network Fabric SpeedEnum100GbE/400GbE/800GbERequired
GPU Cluster DesignationTextBest Practice
Liquid Cooling Manifold ConnectedBooleanY/NRequired
Coolant Quick-Connect VerifiedBooleanY/NRequired
Rack Grounding / BondingBooleanY/NRequired (NEC)
Rack Seismic BracingBooleanY/NRequired (IBC)
Subscribe to download this template

5 Role Variants Available

GC / EPC
200-300
fields · Complete master report
Owner / Client
40-60
fields · Executive summary
Subcontractor
50-80
fields · Trade-specific
Safety / HSE
60-80
fields · Deep safety detail
Foreman / Field
30-50
fields · Quick field entry

Frequently Asked Questions